Optimization of Cooling Load for Different Greenhouse Models in Malaysia
Abstract
In this paper, the building energy analysis program (DOE-2.1E) is used to investigate the reduction in thermal gains and cooling load for agricultural greenhouse. The greenhouse  located in Kuala Lumpur (latitude =3.12o and longitude = -101.60o) and designed with a modified arch roof type with a length of 6 m, width of 3 m, gutter and gable heights of 2.4 m and 0.6 m, respectively. Three models such as: (1) an internal, movable 50% shade screen mounted directly above the floor, with a span of 3 m from gutter to gutter; (2) a double envelope roof that is elevated 0.6 m from the ceiling; and (3) an internal, movable shade screen with a double envelope roof have been selected for comparison with the original greenhouse. The comparison is based on thermal gains and cooling load. The results showed that the internal, movable 50% shade screen was found to be the most effective in reducing maximum cooling load requirement (at 14.89%); the double envelope roof models with and without shading reduced maximum cooling load by 10.11 % and 9.39 %, respectively.
Keywords
Full Text:
PDFDOI (PDF): https://doi.org/10.20508/ijrer.v4i1.990.g6242
Refbacks
- There are currently no refbacks.
Online ISSN: 1309-0127
Publisher: Gazi University
IJRER is indexed in EI Compendex, SCOPUS, EBSCO, WEB of SCIENCE (Clarivate Analytics)and CrossRef.
IJRER has been indexed in Emerging Sources Citation Index from 2016 in web of science.
WEB of SCIENCE in 2025;
h=35,
Average citation per item=6.59
Last three Years Impact Factor=(1947+1753+1586)/(146+201+78)=5286/425=12.43
Category Quartile:Q4